OXYSWING® PSA Oxygen Generators – Twin-Tower Systems
Overview | Products | Technology | Applications
OXYSWING® Modular PSA Oxygen Generators
The unique and modular design of the OXYSWING® Modular PSA Oxygen Generators (international patents pending) offers you the following advantages:
The key features of the OXYSWING® Twin-Tower PSA Oxygen Generators are:
- Unlimited Flexibility
The best fit solution to any oxygen supply requirement. No risk for excessive oversized systems;
- Easy System Adjustment
In case your oxygen supply conditions will change, simply adjust your OXYSWING® system by varying the number of PSA modules. Just by yourself, no other modifications to the system required;
- Lowest Energy Consumption
Energy cost is your major expense, not depreciation. Fast pay-back assured. Let OXYSWING® really make you save money;
- High Reliability
First-class components, stainless steel process piping and valve bodies, heavy-duty PLC. It should work. Always.
- High Oxygen Discharge Pressure
Unmatched high oxygen discharge pressure which allows direct oxygen supply to your application without the need for expensive oxygen boosters. Reliable and no additional investments;
- Compact
No other PSA oxygen system on the market with such limited space requirements. Ideal for container solutions;
- Easy Fleet Management
Identical components for the entire model range = limited spare part management, easy maintenance;
- Certified Medical Device
Certified as Class IIB medical device according to the Medical Device Directive 93/43/CE. Approved for intensive-care oxygen supply.
OXYSWING®
PSA Generator |
Oxygen Production Flow (Nm³/h) / (scfh) |
Length
(mm) / (inch) |
Width
(mm) / (inch) |
Heigth
(mm) / (inch) |
Weight
(kg) / (lbs) |
90 vol.% |
93 vol.% |
95 vol.% |
OS-8 |
2,6 / 101 |
2,6 / 98 |
2,5 / 96 |
560 / 22 |
780 / 31 |
1.672 / 66 |
306 / 674 |
OS-16 |
5,3 / 204 |
5,2 / 200 |
5,1 / 197 |
560 / 22 |
1.048 / 41 |
1.672 / 66 |
457 / 1,008 |
OS-24 |
8,0 / 308 |
7,8 / 301 |
7,6 / 293 |
560 / 22 |
1.316 / 52 |
1.672 / 66 |
609 / 1,342 |
OS-32 |
10,6 / 409 |
10,3 / 397 |
10,1 / 389 |
560 / 22 |
1.584 / 62 |
1.672 / 66 |
760 / 1,676 |
OS-40 |
13,1 / 505 |
12,8 / 493 |
12,5 / 482 |
560 / 22 |
1.852 / 73 |
1.672 / 66 |
912 / 2,010 |
OS-48 |
15,6 / 601 |
15,1 / 582 |
14,9 / 574 |
560 / 22 |
2.120 / 83 |
1.672 / 66 |
1.063 / 2,344 |
Feed Air Pressure = 7,0 bar(g) / 100 psig
Oxygen Discharge Pressure = 6,0 bar(g) / 87 psig
Oxygen Dew Point = -60 °C / -76 F at atmospheric pressure
Feed Air Consumption = Oxygen Production Flow x 10
Each OXYSWING® Modular PSA Oxygen Generator can easily be upgraded at any time simply by adding modules or by installing a so-called Dual-Bank in parallel without additional modifications.
A Dual-Bank is a PSA oxygen generator identical to the standard OXYSWING® PSA oxygen generators, but without PLC and power supply, and which will be installed parallel to the standard generator. The Dual Bank will get its power and control signals from the OXYSWING® PSA oxygen generator through a single cable connection (master/slave principle).
One OXYSWING® PSA oxygen generator is able to control up to maximum of two Duals Banks in parallel.
OXYSWING®
PSA Generator |
Master Unit with #2 Dual Banks
Oxygen Production Flow (Nm³/h) / (scfh) |
Master Unit with #2 Dual Banks
Oxygen Production Flow (Nm³/h) / (scfh) |
90 vol.% |
93 vol.% |
95 vol.% |
90 vol.% |
93 vol.% |
95 vol.% |
OS-8 |
5,2 / 202 |
5,2 / 196 |
5,0 / 192 |
7,8 / 303 |
7,8 / 294 |
7,5 / 288 |
OS-16 |
10,6 / 408 |
10,4 / 400 |
10,2 / 394 |
15,9 / 612 |
15,6 / 600 |
15,3 / 591 |
OS-24 |
16,0 / 616 |
15,6 / 602 |
15,2 / 586 |
24 / 924 |
23,4 / 903 |
22,8 / 879 |
OS-32 |
21,2 / 818 |
20,6 / 794 |
20,2 / 778 |
31,8 / 1,227 |
30,9 / 1,191 |
30,3 / 1,167 |
OS-40 |
26,2 / 1,010 |
25,6 / 986 |
25,0 / 964 |
39,3 / 1,515 |
38,4 / 1,479 |
37,5 / 1,446 |
OS-48 |
31,2 / 1,202 |
30,2 / 1,164 |
29,8 / 1,148 |
46,8 / 1,803 |
45,3 / 1,746 |
44,7 / 1,722 |
Feed Air Pressure = 7,0 bar(g) / 100 psig
Oxygen Discharge Pressure = 6,0 bar(g) / 87 psig
Oxygen Dew Point = -60 °C / -76 F at atmospheric pressure
Feed Air Consumption = Oxygen Production Flow x 10
Standard Components
- Feed Air Filters
- Adsorber Vessel Module(s)
- Pneumatic Valves with SS316L Bodies
- Internal Piping & Fittings in SS316
- Exhaust Mufflers
- Oxygen Pressure Regulation
- Local Instrumentation
- Control System with Allen-Bradley PLC
- Pressure Switch for Automated Idle-Mode
Options
- Dual Bank Unit (max. 2)
- Oxygen Analyzer with Zirconium Oxide Cell
- Electronic Product Flow Meter
- Dew Point Analyzer
- Semi-Graphical HMI Interface

- Sterile Filters
- Telemetry
- High Pressure Oxygen Booster
- Oxygen Cylinder Filling System